DU NOUY TENSIOMETER PDF

CSC Scientific DuNouy Precision and Interfacial Tensiometers. Provides rapid surface tension measurements—15 to 30 secinds. $7, – $8, The force maximum is determined with a modern tensiometer (K, K20) with the help of an With the Du Noüy ring method, a correction must be made to the . The CSC-Dunouy Tensiometer is a precision instrument used for measuring both The CSC-Dunouy Tensiometers (Fig.1 and 2) use a fine torsion wire for.

Author: Doushura Doushicage
Country: Luxembourg
Language: English (Spanish)
Genre: Photos
Published (Last): 10 April 2008
Pages: 286
PDF File Size: 14.56 Mb
ePub File Size: 10.31 Mb
ISBN: 526-8-37240-379-1
Downloads: 97857
Price: Free* [*Free Regsitration Required]
Uploader: Taushakar

The Journal of General Physiology. Earlier, torsion wire balances were commonly used. English software For TEN This is called interfacial surface tension. D Wikipedia, tensiomerer free encyclopedia. The maximum force is used for the calculations, and empirically determined correction factors are required to remove the effect caused by the finite diameter of the ring:. The measurement is performed with a force tensiometerwhich typically uses an electrobalance to measure the excess force caused by the liquid being pulled up and automatically calculates and displays the surface tension corresponding to the force.

Platinum ring perimeter length. How can we help you? The force required to raise the tebsiometer from the liquid’s surface is measured and related to the liquid’s surface tension. To measure tensiometef surface tension between a liquid and the air, the Tensiometer duNouy ring is placed below the surface of the liquid. This page was last edited on 3 Octoberat Your browser does not support the video tag.

  FU KIAU BUNSEKI PDF

The force needed to break the boundary going from the floating liquid to the greater density liquid is measured by pushing the ring down through noky boundary. Measuring instruments Laboratory equipment. The most common correction factors include those by Zuidema and Waters for liquids with low interfacial tensionHuh and Mason which covers a wider range than Zuidema-Watersand Harkins and Jordan more precise than Huh-Mason while still covering the most widely used liquids.

Du Noüy ring method – Wikipedia

Views Read Edit View history. Du Nouy ring method: This test is performed by pulling the ring upward through the surface of the liquid.

Retrieved from ” https: By using this site, you agree to the Terms of Use and Privacy Policy. Copyright Beijing United Test Co. Fundamentals of Interface and Colloid Science: Item Quantity Frame 1 set Platinum ring R9. There are applications where the surface tension at the boundary of tensiometef liquids needs to be measured.

  IRFANVIEW DJVU TO PDF

The du Nouy ring method is one technique by which the surface tension of a liquid can be measured. Surface Tensiometer Du nouy ring tensiometer. The force needed for the ring to break the surface overcome the surface tension is determined.

Documents Manual, packing list, certificate.

Commons category link is on Wikidata. The method involves slowly lifting a ring, often made of platinum, from the surface of a liquid.

The Tensiometer for this test needs to pull the ring up through the boundary between the lower, higher density liquid, and the liquid that is floating above.

Rockwell hardness tester Brinell hardness tester Vickers hardness tester Universal hardness tester Micro vickers hardness tester Hardness block.

Du Noüy ring method

The method involves slowly lifting a ring, often made of platinum, from the surface of a liquid. The force needed to break through the surface of the higher density liquid is recorded as interfacial surface tension.

In other projects Wikimedia Commons.