Beninca Brain 24 Manual. Instruction Manual for Beninca Brain 24 Control Panel. Copy to Email · Send to Mobile. Print. Download · Buy Product. Name. 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 8k2 Command central for 1/2 24Vdc motor, for single or sliding doors: BRAINY Beninca Brain 24 – EasyGates Manuals & Guides. L Rev. 02/06/02 CENTRALE DI COMANDO CONTROL UNIT STEUEREINHEIT CENTRALE DE.

Author: Vizragore Kajinn
Country: Sweden
Language: English (Spanish)
Genre: Music
Published (Last): 2 March 2016
Pages: 50
PDF File Size: 16.58 Mb
ePub File Size: 16.1 Mb
ISBN: 927-4-71464-630-1
Downloads: 88197
Price: Free* [*Free Regsitration Required]
Uploader: Mezijinn

Adjustment of braking With braking enabled SLD logic: Limit switches not provided. For example, with a 20s stroke, preset 17s to start the braking phase, 3s in advance with respect to end of movement. Comply with regulations in force! With 2ch logic On: OFF mloc Selects the type of electric lock used.

Beninca Brain 24 Manual | Egates Knowledge Base

Control Unit Beninca CP. The operation mode of the amperometric sensor is selected ei- ther the limit switches are provided or not.

The preset time should therefore be lower than the real stroke of the operator. Radio receiver enabled only for rolling-code transmitters. OFFas the end of operation is determined 11 only by the triggering of the limit switch or by the amperometric sensor.

  DANTE AGOSTINI METODO PER BATTERIA VOL 2 PDF

Add to my manuals Add. OFF serL Service light function is enabled or disabled on output Similarly to the safety edge activation, the control signal is sent to stop and reverse movement for approx.

Don’t have an account? Receiver enabled for rolling-code and programmable code 2 self-learning and Dip Switch.

Comments to this Manuals Your Name. Make sure the devices are correctly connected i. Function Description Motor 1 Connection, motor 1: OFF Blc The lock function is enabled or disabled. Blinking is activated 3s before the motor starts. To print the manual completely, please, download it. The speed of the motor during braking is determined by the SLDS parameter value. Page of 9 Go. With the gate open or in the opening phase the intervention of the photocell causes automatic closing after 3 s.

For example, with the leaves completely closed the display is as follows: Returns the control unit to the default values.

With 2ch logic Off: After waiting 60s the control unit quits programming mode and switches off the display.

Radio receiver enabled only for rolling-code transmitters. If the code is not valid, the wording Err is displayed.

  LINCAT EB3F PDF

Beninca BRAINY24 24Vdc Control panel for 1 or 2 motors REPLACES BRAIN24

Brainn performance of the output is preset by 2ch parameter, see previous parameter. Only motor 1 operating. It’s a community-based project which helps to repair anything. Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the software release.

Beninca BRAINY24 24Vdc Control panel for 1 or 2 motors REPLACES BRAIN24

In the event of failure it switches on according to the following scheme. Before each opening manoeuvre the power supply is interrupted for the time set by the parameter TLOC. An incorrect setting of these parameters may result in an hazard.

The amperometric sensor activation is interpreted by the control unit as limit switch. For the light control use the auxiliary relay. To use this function, close the limit switch contacts with jumpers. Active only with TCA: Press the transmitter key to be assigned to this function.