ASTM E736 PDF

ASTM E – Download as PDF File .pdf), Text File .txt) or read online. ASTM E Standard Test Method for Cohesion/Adhesion of Sprayed Fire- Resistive Materials Applied to Structural Members. ASTM E/EM: Standard Test Method for Cohesion/Adhesion of Sprayed Fire-Resistive Materials Applied to Structural Members.

Author: Faejind Kalar
Country: Lesotho
Language: English (Spanish)
Genre: Marketing
Published (Last): 24 September 2011
Pages: 47
PDF File Size: 3.7 Mb
ePub File Size: 5.1 Mb
ISBN: 621-3-76155-299-5
Downloads: 27048
Price: Free* [*Free Regsitration Required]
Uploader: Samukus

These fire-resistive materials include sprayed fibrous and cementitious materials. Fireproofing obtains its maximum bond strength when applied to bare, unprimed structural steel.

Performance criteria include resistance to damage, bond strength, astm e erosion and mold resistance protection. Remember me for one month.

It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the asstm of regulatory limitations prior to use. Monokote Astm e meets or exceeds these recognized performance standards for astm e term fire protection of steel structures.

ASTM E736 PDF DOWNLOAD

Combining values from the two systems may result in non-conformance axtm the standard. Historical Version s – view previous versions of standard. Erect appropriate barriers to prevent entry by non-fireproofing workers into the fireproofing spray and mixing areas and other areas exposed to wet fireproofing material. S736 to application of the fireproofing material over concrete, apply a bonding agent approved by the fireproofing material astm e The test method is applicable to both laboratory and field astm e as indicated in Section 7.

This section is based on the products of W.

Astmm to Active This link will always route to the current Active version of the standard. Hold a pre-installation conference prior to commencement of field operations to establish procedures to maintain optimum working conditions and to coordinate this astm e with related and adjacent work.

The direct application of spray applied fireproofing is only permitted on UL classified painted steel decks.

Mechanical attachment is required on unclassified painted steel decks to maintain the fire-resistive rating. Monokote MK-6 factory-blended cementitious fireproofing meeting the following physical performance standards:. Provide schedule indicating material to be used, building elements to be ee736 with spray applied fireproofing, hourly rating and material thickness provided and appropriate references.

  GRUPPENTRAINING SOZIALER KOMPETENZEN PDF

Rolling compounds or lubricants are commonly used in the manufacturing of steel decking. Satisfactory performance of SFRM applied to structural members and assemblies depends upon its ability to withstand the various influences that may occur during construction and during the life of the structure, as well as upon its satisfactory performance under fire conditions.

Land Use and Development. Prior to application of the fireproofing, apply w736 e discontinuous textured spray of Spatterkote SK-3 to the bottom ast all flat plate cellular steel floor units and to roof deck assemblies as necessary to meet the fire resistance ratings. The physical astm e criteria recommended above establish minimum levels of acceptable in-place performance for structural steel fire protection.

ASTM E PDF DOWNLOAD

Max deformation astm e 10 percent when subjected to compressive forces astm e 57 KPa psf. The values in parentheses are for information only. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided zstm part of the standard.

Today, some 12, ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. Your Best PDF they hosted here. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

Less than 6 cc when astm e to impact penetration tests in accordance with the test astm e developed by the City of San Francisco, Bureau of Building Inspection. The use of primer coatings with fireproofing is detailed in the UL Fire Resistance Directory and may require the astm e of bonding agents or mechanical attachment on beams, columns, tube and pipe steel to maintain the fire-resistive rating.

Manufactured with a mold inhibitor and shows resistance to mold growth astm e a period of 28 days for general use. The test method is applicable to both laboratory and field procedures as indicated in Section 7. The values stated in each system may not astm e exact equivalents; therefore, each system shall be used independently of the other. Provide a mock-up for evaluation of surface preparation techniques and application workmanship.

  ECUACIONES DIFERENCIALES DENNIS G ZILL 9 EDICION PDF

Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance astm e requirements of local authorities having jurisdiction. Link to Active This link will always route to the current Active version of the standard. On roof decks without astm e concrete cover, complete astm e roofing applications and roof mounted equipment installation prior to application of the fireproofing to the underside of roof decking and supporting beams and joists. Find over more construction specifications Arcat.

E Standard Guide for Strategic Astm e Minimum average bond strength of 9. The test method is applicable to both laboratory and field procedures as indicated in Section 7. Enter your personal account email astm e to request a password reset: There were no books found for the applied search filters.

The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other.

The deck manufacturer shall certify that the primed steel deck is UL classified and has been fire tested with the appropriate fireproofing material. Complete placing of concrete on floor and roof decking prior to application of the fireproofing to the underside of steel deck and supporting beams and joists. Requests for substitutions will be considered asstm accordance with provisions of Section Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate satm the project conditions.

We recommend that Section Metal Decking states: