ASTM C1090 PDF

Measuring Changes in Height of Cylindrical Specimens of Hydraulic-Cement Grout. ASTM C Standard Test Method for Measuring Changes in Height of Cylindrical Specimens of Hydraulic-Cement Grout. ASTM C/CM: Standard Test Method for Measuring Changes in Height of Cylindrical Specimens of Hydraulic-Cement Grout.

Author: Faesho Nibar
Country: India
Language: English (Spanish)
Genre: Marketing
Published (Last): 4 January 2010
Pages: 492
PDF File Size: 1.2 Mb
ePub File Size: 10.32 Mb
ISBN: 960-1-75805-262-9
Downloads: 65585
Price: Free* [*Free Regsitration Required]
Uploader: Nell

ASTM International – Standard References for ASTM C / CM – 15

The height change of a 3-inch mm -diameter by 6-inch mm -tall cylindrical specimen was measured in accordance with ASTM C Link to Active This link will always route to the current Active version of the standard. I married on 30 th June now having one b Two cylindrical specimens with the same dimensions as those used for the ASTM C test method were prepared in which the change in height was measured at four points on the top surface of the specimens using a micrometer in accordance with ASTM C at 1, 3, 7, 14, and 28 d see figure This approach provided more simplicity in the execution of the test, rather than using a projector lamp, magnifying lens, and indicator charts as described in ASTM C see figure The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other.

  D&D SCATOLA ROSSA PDF

An exception is made when the options described in the section on test conditions are exercised.

The degree of restraint varies with the mixture viscosity and degree of hardening. For cementitious grouts, saturate the surface up to SSD. Sieve size is identified asrm its standard designation in Specification E The glass plate was removed from the top of the test specimen after 24 h.

Testing of shrinkage for concrete – grout. After removal, the thickness of the glass plate was awtm with a caliper at the points of contact between the glass plate and the micrometer. Some values have only SI units because the inch-pound equivalents are not used in practice. Newer Post Older Post Home. The laser approach has been compared with the original setup, and similar results were obtained.

Combining values from the two systems may result in non-conformance with the standard. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  AXIOMAS DE LA COMUNICACION PAUL WATZLAWICK PDF

Though not recommended by the ASTM standards, and in order to provide the lowest friction possible, an acetate sheet was used in between the test specimen and the mold. This thickness was asfm added to the four-reading initial measurement. The height change results in both test methods are expressed in terms of percentage increase or decrease of the original specimen height.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

[email protected]: Testing of shrinkage for concrete – grout.

These test methods cover procedures for assessing the adhesion of coating films to metallic substrates by applying and removing pressure-s In both test methods, there is always a certain degree of friction between the specimen’s sides and the inner surface of the metallic mold. Historical Version s – view previous versions of c1009.

The alternative designation given in parentheses is for information only and does not represent a different standard sieve size.