AS NZS 3002 PDF

Australian/New Zealand Standard™. Electrical installations—Shows and carnivals. A. S. /NZS This is a free 7 page sample. Access the full version online. AS/NZS Electrical installations – Shows and carnivals. standard by Australian/New Zealand Standards, 01/01/ View all product details. Find the most up-to-date version of AS/NZS at Engineering

Author: Guk Bataxe
Country: Namibia
Language: English (Spanish)
Genre: Literature
Published (Last): 15 February 2009
Pages: 94
PDF File Size: 14.25 Mb
ePub File Size: 20.42 Mb
ISBN: 116-7-57932-260-9
Downloads: 71432
Price: Free* [*Free Regsitration Required]
Uploader: Fenriran

It is recommended that for typical installations: It is recommended that this connection be made via a removable link.

AS/NZS – Standards Australia

Extra low voltage devices must be clearly identified and have plug tops and bases that cannot be inadvertently connected to higher voltage supplies. This type of protection will minimise the disruption to major sections of the lighting installations in the event of a current leakage to earth.

For information see testing of electrical leads and residual current devices RCDs. For general areas, illumination to an average as low as 10 lux at ground level with no area less than 5 lux is acceptable. Other people who qs this product also bought Lighting should be energised approximately 1 hour before sunset to allow time for any unserviceable lights to be repaired before sunset.

All electrical outlets and electrically operated equipment in areas available to the public must be protected by RCDs. Temporary 302 available nza the public at night, including concert areas, should always be ws.

All permanent venues and egress paths must be able to be illuminated to 40 lux by lighting that is:. The preferred leakage tripping current is 30 milliamps and they must be tested every 12 months in accordance with the requirements of AS Electrical cables should not be accessible to members of the public.

Home Electrical and lighting requirements — public buildings. Sets out requirements for the supply of electricity at low-voltage by wiring systems to power consuming devices used for accommodation, entertainment or display purposes within – a concessions; b tents; c living quarters; and d other structures associated with events with a maximum duration of four weeks. Eelectrical contractors performing work in a public building must submit a Form nze certificate of electrical compliance to the local government, to certify that permanent and temporary electrical installations are compliant with the unique requirements of the regulations and other statutory obligations.

  BADOL DINER PROTHOM KODOM FUL BY HUMAYUN AHMED PDF

International Classification for Standards ICS is an international classification system for technical standards.

AS/NZS – Quick Download AWS, SIA, BS EN, ISO Codes

Leads must not be placed on the ground in areas where there is pedestrian traffic. All electrical outlets and supplies must have circuit breakers to protect against overload. See Testing of electrical leads and residual current devices RCDs. References This document may make references to other documents. A tag to identify the item, test date and the electrical worker should be fixed to the tested equipment.

They should not be controlled at the mixer desk. Two generators or a supply authority supply, plus another generator, are acceptable alternatives provided that the venue lighting supplies are distributed between both. Safety lighting must be 302 separate supply to normal or emergency lighting and must not be dimmed or modulated.

Produced by Public Health.

Temporary electrical installations All electrical qs and electrically operated equipment in areas available to the public must be protected by RCDs. Electricity Safety Regulations Ministry: For the purposes of this Standard, events include exhibitions, shows, carnivals, scouting jamborees, army camps and the like. About us Improving health in WA Health for The owners and operators of the following installations must ensure that the installations are periodically assessed as set out below, to determine whether they are electrically safe and otherwise comply with these regulations For crowded areas, especially for concerts and areas licensed to consume alcohol, there must be a system in place that will allow areas to flood light instantaneously in the event of an emergency.

  FLUKE 9143 PDF

Typical temporary installations consist of submains, subboards and electrical leads. For outdoor events, large signs illuminated by two light sources, and large enough to make the exit location obvious to patrons must be used.

Electrical and lighting requirements – public buildings

3020 supplies and controls for these lights should be independent of theatrical or production lights and controlled from a location attended at all times by a designated person. New equipment requires a tag to define when it was brought into service. It is designed to cover every economic sector and virtually every activity of the humankind where technical standards may be used.

A copy of the Form 5: Emergency lighting Enclosed venues must have emergency lighting that will operate if the main electrical source fails. Open search bar Open navigation Submit search.

Where electrical outlets are provided, there should be a tie bar to allow electrical cords to be secured, to prevent tension on the electrical outlet. Maximum viewing distance Minimum pictorial element height mm 16 24 32 For viewing distances greater than 32 m, in accordance with the following equation: For events where lighting will be dimmed or extinguished, stairs, ramps and egress paths must be illuminated by safety lighting. Print this page Twitter Youtube LinkedIn.

Dimensional interchangeability requirements for pin and contact-tube accessories AS Amusement rides and devices IEC Plugs socket-outlets and couplers for industrial purposes. Extra low voltage equipment Extra low voltage devices must be clearly identified and have plug tops and bases that cannot be inadvertently connected to higher voltage supplies. Expand the box to see details.